Notes to installation of the ball valves
■ Mount ball valves up- and downstream of the
meter.
■ Mount a ball valve with bore M10x1 for direct
sensors in the supply. This is required for the
installation of the supply sensor.
■ For symmetrical temperature sensor instal-
lation, mount an identical ball valve in the
return. This one is used for mounting the
return sensor.
Mounting heating-/cooling energy meter
■ Flush the system thoroughly before installing
the heating-/cooling energy meter.
■ Close valves and release pressure.
■ Dismount the existing ow sensor or meter
blank.
■ Use only new and awless sealing material
and check the seal face for damage.
■ Install the new ow sensor according to the
correct ow direction and installation position.
■ Turn heat computer to desired reading posi-
tion.
Mounting temperatur sensors
■ The installation of the temperature sensors
should be preferably symmetrical and direct
installation.
■ Do not remove the return sensor if already
mounted on the VMU. This is also valid for
all the safety seals which are mounted on the
device as a standard.
■ Sensors are colour-coded (red= hot; blue=cold).
■ The connecting cables may not be buckled,
extended or shortened.
■ The seal at the sensor installation point on the
measuring capsule may not be damaged.
■ Remove locking screw and seal at the ball
valve completely, if existing.
■ Attach the O-ring to the installation aid (the
2nd O-ring is only a spare O-ring). Using the
installation aid, insert the O-ring into the
installation point according to DIN EN 1434
with a slight circular motion.
■ Using the other end of the installation aid
bring the O-ring into the correct position.
■ Insert the 2 halves of the plastic connector
into the sensor’s three notches (crimps) and
press them together.
■ Use the installation aid as positioning aid.
■ Insert the temperature sensor into the installa-
tion point and screw it in tightly until the dead
stop of the seal on the 12-point is reached
(mounting torque 3-5 Nm).
■ The temperature sensor installation point
which is optionnally integrated in the ow
sensor must be secured.
■ Secure the sensor after installation against
unauthorised removal with appropriate sealing
(available as a sealing set)!
Installation DF-adapter