zelsius
®
C5-ISF
Installation and operating manual
electronic compact heat meter
with single-jet flow sensor ISF
M-Bus, wM-Bus and 3 inputs/outputs optional
q
p
0,6/1,5/2,5 m
3
/h
EnergyMetering
All that counts.
Vista de página 0
1 2 3 4 5 6 ... 11 12

Resumo do Conteúdo

Página 1 - All that counts

zelsius® C5-ISFInstallation and operating manualelectronic compact heat meterwith single-jet flow sensor ISFM-Bus, wM-Bus and 3 inputs/outputs optional

Página 2 - Installation manual

10Important Note:The optical interface has to be activated by means of the OptoHead through keypress before reading out of the de vice.Devices, which

Página 3 - (optional)

11Ebene 3 Level 1 Ebene 4 Setting of water-glycol-mixtures for zelsius C5 „Glycol Meter“Selection of the display „E 0“ on Level 1 Press the button fo

Página 4

12Disposal Attention: This device contains a non-remova-ble and non-rechargeable lithium battery. Batteries contain substances, which could harm the

Página 5 - M-Bus (optional)

Installation manualGeneral informationWith zelsius® C5-ISF you have acquired one of the most up-to-date, modern heat meters cur-rently available on th

Página 6 - Installation instructions

3Technical data temperature sensorsPlatinum resistance Pt 1000Sensor diameter/type mm Standard: 5,0 (DS according to EN 1434); other sizes on demandTe

Página 7 - Montage DF- Adapter

4Technical data calculatorTemperature range °C 0…105Temperature difference range K 3…80Display LCD 8-digit + additional characterAmbient temperature

Página 8 - Consumer

5M-Bus (optional)The optional M-Bus interface complies with the norm 1434-3 and operates with 2400 baud xed.The two conductors can be connected in

Página 9 - Status display / Error codes

6Subject to modications and errors excepted. Any liability for misprints excluded. SAP139726_150529_ENZENNER International GmbH & Co. KGRömerstad

Página 10 - Supply temperature

7Notes ball valves Mount ball valves up- and downstream of the meter. Mount a ball valve with bore M10x1 for direct sensors in the supply. This is

Página 11 - 1. this month to now

8Putting into use Open valves carefully and check installation for leakage. If the sleep mode of the counter is enabled (Display: SLEEP 1), then i

Página 12 - Disposal

9Status display / Error codesThe symbols in the table below show the meter’s operational status. The status messages only appear in the main display (